top of page

Wall Bushings

362kV RIP Wall Bushing

362kV RIP Wall Bushing

RIP 362kV High-Voltage Wall Bushings

 

  • ​ Application: indoor – indoor, outdoor – indoor, outdoor – outdoor

  •  Standard: IEC 60137 – 2017

  •  Inner Insulation Type: RIP & RIS. According to requirements.

  •  External Insulation Type: Polymer (silicone rubber with Uv protection) & Porcelain

  •  Rated Current: 630A – 5000A

  •  BIL – 1175kV

  •  SIL – 950kV

  •  Power-frequency withstand voltage (dry) – 510kV

  •  Dielectric dissipation factor (tan δ)- ≤0.4%

  •  Partial discharge (pC)- ≤5 pC

  •  Test tap is be provided.

123kV RIS Wall Bushing

123kV RIS Wall Bushing

RIS 126kV Wall Bushings
 

  • Application: indoor – indoor, outdoor – indoor, outdoor – outdoor

  • Standard: IEC 60137 – 2017

  • External Insulation Type: Polymer (silicone rubber with Uv protection) & Porcelain. According to requirement.

  • Inner Insulation Type: RIP & RIS.

  • Rated Current: 630A – 12,000A

  • BIL – 550kV

  • Power-frequency withstand voltage: dry – 230kV, wet – 230kV

  • Dielectric dissipation factor (tan δ)- ≤0.4%

  • Partial discharge (pC)- ≤5 pC

  • Test tap is be provided.

245kV RIP Wall Bushing

245kV RIP Wall Bushing

RIS 252kV Wall Bushings

​

  •  Application: indoor – indoor, outdoor – indoor, outdoor – outdoor

  •  Standard: IEC 60137 – 2017

  •  External Insulation Type: Polymer (silicone rubber with Uv protection) & Porcelain

  •  Inner Insulation Type: RIP & RIS

  •  Rated Current: 630A – 8000A

  •  BIL – 1050kV

  •  SIL – 850kV

  •  Power-frequency withstand voltage: dry – 460kV, wet – 460kV

  •  Dielectric dissipation factor (tan δ)- ≤0.4%

  •  Partial discharge (pC)- ≤5 pC

  •  Test tap is be provided.

72.5kV RIS Wall Bushing

72.5kV RIS Wall Bushing

RIS 72.5kV Wall Bushings

​

  • Application: indoor – indoor, outdoor – indoor, outdoor – outdoor

  •  Standard: IEC 60137 – 2017

  •  External Insulation Type: Polymer (silicone rubber with Uv protection) & Porcelain. According to requirements.

  •  Inner Insulation Type: RIP & RIS.

  •  Rated Current: 630A – 12,500A

  •  BIL – 325kV

  •  Power-frequency withstand voltage: dry – 140kV, wet – 140kV

  •  Dielectric dissipation factor (tan δ)- ≤0.4%

  •  Partial discharge (pC)- ≤5 pC

  •  Test tap is be provided.

170kV RIS Wall Bushing

170kV RIS Wall Bushing

RIS 172kV Wall Bushing

 

  • Application: indoor – indoor, outdoor – indoor, outdoor – outdoor

  • Standard: IEC 60137 – 2017

  • Inner Insulation Type: RIP & RIS. According to requirement.

  • External Insulation Type: Polymer (silicone rubber with Uv protection) & Porcelain

  • Rated Current: 630A – 12,000A

  • BIL – 750kV

  • Power-frequency withstand voltage (dry) – 325kV

  • Dielectric dissipation factor (tan δ)- ≤0.4%

  • Partial discharge (pC)- ≤5 pC

  • Test tap is be provided.

52kV RIS Wall Bushing

52kV RIS Wall Bushing

RIS 52kV Wall Bushings

​

  • Application: indoor – indoor, outdoor – indoor, outdoor – outdoor

  •  Standard: IEC 60137 – 2017

  •  External Insulation Type: Polymer (silicone rubber with Uv protection) & Porcelain. According to requirement.

  •  Inner Insulation Type: RIP & RIS. According to requirement.

  •  Rated Current: 630A – 12,000A

  •  BIL – 250kV

  •  Power-frequency withstand voltage: dry – 95kV, wet – 95kV

  •  Dielectric dissipation factor (tan δ)- ≤0.4%

  •  Partial discharge (pC)- ≤5 pC

  •  Test tap is be provided.

bottom of page